Customization: | Available |
---|---|
Breaking Capacity: | High Voltage Circuit Breakers |
Operation: | Manual Type |
Still deciding? Get samples of US$ 5000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
TOVR outdoor high-voltage AC vacuum circuit breaker automatic recloser (hereinafter referred to as "recloser") adopts the vacuum arc extinguishing principle. It is a three-phase AC 50Hz/60Hz outdoor high voltage switch. It is mainly applied in rural and urban power grids, 10-35kV outdoor power distribution system to divide and combine load current, overload current and short-circuit current; it can also be used in other similar places. The TOVR series outdoor AC high-voltage vacuum circuit breaker auto recloser complies with standards GB 1984 "AC High-Voltage Circuit Breaker" and the International Electrotechnical Commission IEC 60056 "High-Voltage AC Circuit Breaker".
Standard
IEC62271-100/105/200, IEC60265-200,
Service condition:
-Ambient air temperature: -40 °C ~ 60 °C
- Altitude: no more than 2000m
- The surrounding air may be contaminated by dust, smoke, corrosive gases, steam or salt spray;
- The wind speed does not exceed 34m/s (equivalent to 700Pa on the cylinder surface);
- Vibration or ground motion from switchgear and control equipment can be ignored;
- Pollution level: Level III.
- If service in a different condition, please negotiate with the manufacturer.
No. | Item | Unit | Data |
1 | Rated voltage | kV | 34.5 |
2 | Maximum operating voltage (nominal) | kV | 36.2 |
3 | Rated current | A | 630/800 |
4 | Rated frequency | Hz | 50/60 |
5 | Rated short circuit making current | kA | 12.5/16 |
6 | Rated short circuit breaking current | kA | 12.5/16 |
7 | Rated short time withstand current | kA | 12(16)/3s |
8 | Rated peak withstand current | kA | 32.5/42 |
9 | Rated operating sequence | o-0.3s-co-180s-co | |
10 | Rated power frequency withstand voltage (dry/wet) | kV | 70/1min |
11 | Auxiliary and control circuit | kV | 2/1min |
12 | Rated lightning impulse withstand voltage | kV | 150 |
13 | Rated short circuit current breaking times | E2 | |
14 | Mechanical life | 10000 | |
15 | Main circuit resistance | μΩ | ≤200 |
shipping:
sea, air, railway, express
Combining manufacturing experience, new technology and industrial knowledge, TENLEE aims to build advanced power distribution and protection systems.
TENLEE is specialized in manufacturing a comprehensive range of solutions from 12kv to 40.5kv for indoor/outdoor systems: gas insulated switchgears
ring main unit
sf6 free switchgears
vacuum circuit breakers
sf6 circuit breakers
reclosers
load break switches
disconnectors
distribution transformers/power transformers
substations
1. What is the delivery date?
Usually within a month for a HQ.
2. Do you have type tests?
Yes, we have type test in China and we also pass type test in Europe.
3. Do you have other voltage ranges?
Yes, we have 12kv, 24kv and 40.5kv.