Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 5000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb
  • Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb
  • Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb
  • Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb
  • Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb
  • Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Vacuum Circuit Breaker
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE
Standard
IEC 60056,62271
Rated Voltage
36kv
Rated Current
630A, 800A
Mechanical Life
10000
Electrical Life
E2
Operating Mechanism
Permanent Magnet
Service Environment
-40~+60 Celsius
Delivery Time
Within 30 Days
Weight
25kg
Frequency
50/60Hz
Protection
IP65
Transport Package
Wooden Box
Specification
embedded pole, mechanism, built-in CT&VT
Trademark
TENLEE
Origin
China
HS Code
8535210000
Production Capacity
500 Sets Per Month

Product Description

Product Description

TOVR outdoor high-voltage AC vacuum circuit breaker automatic recloser (hereinafter referred to as "recloser") adopts the vacuum arc extinguishing principle. It is a three-phase AC 50Hz/60Hz outdoor high voltage switch. It is mainly applied in rural and urban power grids, 10-35kV outdoor power distribution system to divide and combine load current, overload current and short-circuit current; it can also be used in other similar places. The TOVR series outdoor AC high-voltage vacuum circuit breaker auto recloser complies with standards GB 1984 "AC High-Voltage Circuit Breaker" and the International Electrotechnical Commission IEC 60056 "High-Voltage AC Circuit Breaker".

Standard
IEC62271-100/105/200, IEC60265-200,


Features
1.    The recloser adopts a three-phase pole structure, which has the characteristics of stable and reliable breaking performance, no danger of combustion and explosion, maintenance-free, small size, light weight and long service life. The three-phase primary circuit is installed in the insulating bushing of each phase. When failure occurs in a single-phase, it will not cause a three-phase short circuit.
2.    The recloser adopts a fully enclosed structure with good sealing performance, which helps to improve moisture-proof and anti-condensation performance. It is especially suitable for application in cold or humid areas.
3.    The vacuum arc extinguishing chamber and current transformer are insulated with outdoor epoxy resin and covered with organic silicone, which are resistant to high and low temperature, ultraviolet rays, and aging. It eliminates short circuit failures caused by condensation and is maintenance-free for 20 years, with IP65 protection grade.

 

Product Parameters
No. Item  Unit  Data 
1 Rated voltage kV 34.5
2 Maximum operating voltage (nominal) kV 36.2
3 Rated current 630/800
4 Rated frequency  Hz  50/60
5 Rated short circuit making current  kA 12.5/16
6 Rated short circuit breaking current kA 12.5/16
7 Rated short time withstand current kA 12(16)/3s
8 Rated peak withstand current kA 32.5/42
9 Rated operating sequence   o-0.3s-co-180s-co
10 Rated power frequency withstand voltage (dry/wet) kV 70/1min
11 Auxiliary and control circuit kV 2/1min
12 Rated lightning impulse withstand voltage  kV 150
13 Rated short circuit current breaking times   E2
14 Mechanical life   10000
15 Main circuit resistance μΩ ≤200
  
Detailed Photos
 installation

Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb

Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb 
Packaging & Shipping
 

 

standard packaging: 
wooden box
delivery time: 
within 20 days

 

Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb
Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb





shipping:
sea, air, railway, express
Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb

Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb

Company Profile

Combining manufacturing experience, new technology and industrial knowledge, TENLEE aims to build advanced power distribution and protection systems. 
TENLEE is specialized in manufacturing a comprehensive range of solutions from 12kv to 40.5kv for indoor/outdoor systems: gas insulated switchgears 
ring main unit
sf6 free switchgears
vacuum circuit breakers
sf6 circuit breakers
reclosers 
load break switches
disconnectors
distribution transformers/power transformers
substations 

FAQ

1. What is the delivery date?
Usually within a month for a HQ.
2. Do you have type tests?
Yes, we have type test in China and we also pass type test in Europe. 
3. Do you have other voltage ranges?
Yes, we have 12kv, 24kv and 40.5kv. 

Electrical Hv Outdoor 35kv 36kv 630A 800A Vacuum Circuit Breaker Vcb

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier